Подписаться
Ryan J. White
Ryan J. White
Подтвержден адрес электронной почты в домене uc.edu - Главная страница
Название
Процитировано
Процитировано
Год
Real-time, aptamer-based tracking of circulating therapeutic agents in living animals
BS Ferguson, DA Hoggarth, D Maliniak, K Ploense, RJ White, ...
Science translational medicine 5 (213), 213ra165-213ra165, 2013
3502013
Optimization of electrochemical aptamer-based sensors via optimization of probe packing density and surface chemistry
RJ White, N Phares, AA Lubin, Y Xiao, KW Plaxco
Langmuir 24 (18), 10513-10518, 2008
3432008
Cheapstat: An open-source,“do-it-yourself” potentiostat for analytical and educational applications
AA Rowe, AJ Bonham, RJ White, MP Zimmer, RJ Yadgar, TM Hobza, ...
PloS one 6 (9), e23783, 2011
3322011
Bench-top method for fabricating glass-sealed nanodisk electrodes, glass nanopore electrodes, and glass nanopore membranes of controlled size
B Zhang, J Galusha, PG Shiozawa, G Wang, AJ Bergren, RM Jones, ...
Analytical chemistry 79 (13), 4778-4787, 2007
3152007
Single ion-channel recordings using glass nanopore membranes
RJ White, EN Ervin, T Yang, X Chen, S Daniel, PS Cremer, HS White
Journal of the American Chemical Society 129 (38), 11766-11775, 2007
3082007
An electrochemical supersandwich assay for sensitive and selective DNA detection in complex matrices
F Xia, RJ White, X Zuo, A Patterson, Y Xiao, D Kang, X Gong, KW Plaxco, ...
Journal of the American Chemical Society 132 (41), 14346-14348, 2010
2342010
Comparing the properties of electrochemical-based DNA sensors employing different redox tags
D Kang, X Zuo, R Yang, F Xia, KW Plaxco, RJ White
Analytical chemistry 81 (21), 9109-9113, 2009
2042009
Reagentless, structure-switching, electrochemical aptamer-based sensors
LR Schoukroun-Barnes, FC Macazo, B Gutierrez, J Lottermoser, J Liu, ...
Annual Review of Analytical Chemistry 9, 163-181, 2016
1602016
Exploiting binding-induced changes in probe flexibility for the optimization of electrochemical biosensors
RJ White, KW Plaxco
Analytical chemistry 82 (1), 73-76, 2010
1522010
Hexanethiolate monolayer protected 38 gold atom cluster
VL Jimenez, DG Georganopoulou, RJ White, AS Harper, AJ Mills, D Lee, ...
Langmuir 20 (16), 6864-6870, 2004
1522004
Effects of probe length, probe geometry, and redox-tag placement on the performance of the electrochemical E-DNA sensor
AA Lubin, B Vander Stoep Hunt, RJ White, KW Plaxco
Analytical chemistry 81 (6), 2150-2158, 2009
1332009
Enhancing the analytical performance of electrochemical RNA aptamer-based sensors for sensitive detection of aminoglycoside antibiotics
LR Schoukroun-Barnes, S Wagan, RJ White
Analytical chemistry 86 (2), 1131-1137, 2014
1282014
Ionic conductivity of the aqueous layer separating a lipid bilayer membrane and a glass support
RJ White, B Zhang, S Daniel, JM Tang, EN Ervin, PS Cremer, HS White
Langmuir 22 (25), 10777-10783, 2006
1272006
Label-free, dual-analyte electrochemical biosensors: a new class of molecular-electronic logic gates
F Xia, X Zuo, R Yang, RJ White, Y Xiao, D Kang, X Gong, AA Lubin, ...
Journal of the American Chemical Society 132 (25), 8557-8559, 2010
1242010
Re-engineering aptamers to support reagentless, self-reporting electrochemical sensors
RJ White, AA Rowe, KW Plaxco
Analyst 135 (3), 589-594, 2010
1192010
Fluorescence Detection of Single‐Nucleotide Polymorphisms with a Single, Self‐Complementary, Triple‐Stem DNA Probe
Y Xiao, KJI Plakos, X Lou, RJ White, J Qian, KW Plaxco, HT Soh
Angewandte Chemie International Edition 48 (24), 4354-4358, 2009
1192009
Perspective on the future role of aptamers in analytical chemistry
Y Wu, I Belmonte, KS Sykes, Y Xiao, RJ White
Analytical Chemistry 91 (24), 15335-15344, 2019
1122019
Nanopore platforms for ion channel recordings and single molecule detection and analysis
HS White, RJ White, EN Ervin
US Patent 7,777,505, 2010
1062010
Nanopore platforms for ion channel recordings and single molecule detection and analysis
HS White, RJ White, EN Ervin
US Patent 7,777,505, 2010
1062010
Improving the stability and sensing of electrochemical biosensors by employing trithiol-anchoring groups in a six-carbon self-assembled monolayer
N Phares, RJ White, KW Plaxco
Analytical chemistry 81 (3), 1095-1100, 2009
1052009
В данный момент система не может выполнить эту операцию. Повторите попытку позднее.
Статьи 1–20