Follow
Robert Frost
Robert Frost
Massachusetts General Hospital, Harvard University
Verified email at nmr.mgh.harvard.edu
Title
Cited by
Cited by
Year
Scan time reduction for readout‐segmented EPI using simultaneous multislice acceleration: Diffusion‐weighted imaging at 3 and 7 Tesla
R Frost, P Jezzard, G Douaud, S Clare, DA Porter, KL Miller
Magnetic resonance in medicine 74 (1), 136-149, 2015
1042015
Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging
AZ Lau, EM Tunnicliffe, R Frost, PJ Koopmans, DJ Tyler, MD Robson
Magnetic Resonance in Medicine 73 (3), 995-1004, 2015
982015
High-resolution diffusion MRI at 7T using a three-dimensional multi-slab acquisition
W Wu, BA Poser, G Douaud, R Frost, MH In, O Speck, PJ Koopmans, ...
NeuroImage 143, 1-14, 2016
712016
Markerless high‐frequency prospective motion correction for neuroanatomical MRI
R Frost, P Wighton, FI Karahanoğlu, RL Robertson, PE Grant, B Fischl, ...
Magnetic resonance in medicine 82 (1), 126-144, 2019
652019
3D Multi‐slab diffusion‐weighted readout‐segmented EPI with real‐time cardiac‐reordered k‐space acquisition
R Frost, KL Miller, RHN Tijssen, DA Porter, P Jezzard
Magnetic resonance in medicine 72 (6), 1565-1579, 2014
572014
Implementation and assessment of diffusion‐weighted partial Fourier readout‐segmented echo‐planar imaging
R Frost, DA Porter, KL Miller, P Jezzard
Magnetic resonance in medicine 68 (2), 441-451, 2012
552012
Reducing slab boundary artifacts in three‐dimensional multislab diffusion MRI using nonlinear inversion for slab profile encoding (NPEN)
W Wu, PJ Koopmans, R Frost, KL Miller
Magnetic resonance in medicine 76 (4), 1183-1195, 2016
512016
Simultaneous multi-slab acquisition in 3D multi-slab diffusion-weighted readout-segmented echo-planar imaging
R Frost, P Jezzard, DA Porter, R Tijssen, K Miller
Proceedings of the 21st Annual Meeting of ISMRM, 3176, 2013
242013
Automated detection and reacquisition of motion‐degraded images in fetal HASTE imaging at 3 T
B Gagoski, J Xu, P Wighton, MD Tisdall, R Frost, WC Lo, P Golland, ...
Magnetic resonance in medicine 87 (4), 1914-1922, 2022
222022
Comparison of prospective and retrospective motion correction in 3D‐encoded neuroanatomical MRI
JM Slipsager, SL Glimberg, L Højgaard, RR Paulsen, P Wighton, ...
Magnetic resonance in medicine 87 (2), 629-645, 2022
192022
Feasibility of diffusion tensor and morphologic imaging of peripheral nerves at ultra-high field strength
AB Schmid, J Campbell, SA Hurley, S Jbabdi, JL Andersson, M Jenkinson, ...
Investigative Radiology 53 (12), 705-713, 2018
182018
Prospective motion correction and selective reacquisition using volumetric navigators for vessel‐encoded arterial spin labeling dynamic angiography
R Frost, AT Hess, TW Okell, MA Chappell, MD Tisdall, ...
Magnetic resonance in medicine 76 (5), 1420-1430, 2016
162016
Diffusion-weighted magnetic resonance imaging using 3D mosaic segmentation and 3D navigator phase correction
R Frost, P Jezzard, K Miller, DA Porter
US Patent 8,760,163, 2014
132014
Design and performance of improved Column Parallel CCD, CPC2
Y Banda, P Coulter, D Cussans, C Damerell, E Devetak, J Fopma, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2010
112010
Simultaneous multi-contrast imaging with readout-segmented EPI
NJ Breutigam, R Frost, K Eickel, DA Porter
Proceedings of the 25th Annual Meeting of International Society for Magnetic …, 2017
102017
Data consistent deep rigid MRI motion correction
NM Singh, N Dey, M Hoffmann, B Fischl, E Adalsteinsson, R Frost, ...
Medical Imaging with Deep Learning, 368-381, 2024
82024
Wave-encoded model-based deep learning for highly accelerated imaging with joint reconstruction
J Cho, B Gagoski, TH Kim, Q Tian, R Frost, I Chatnuntawech, B Bilgic
Bioengineering 9 (12), 736, 2022
82022
In M, Speck O, Koopmans PJ, Miller KL
W Wu, BA Poser, G Douaud, R Frost
High-resolution diffusion MRI at 7T using a three-dimensional multi-slab …, 2016
82016
Edge-preserving B0 inhomogeneity distortion correction for high-resolution multi-echo ex vivo MRI at 7T
D Varadarajan, R Frost, A van der Kouwe, L Morgan, B Diamond, E Boyd, ...
International Society for Magnetic Resonance in Medicine 664, 2020
72020
Can nuclear overhauser enhancement mediated chemical exchange saturation transfer (NOE CEST) offer a new insight in acute stroke diagnosis
YK Tee, GW Harston, N Blockley, R Frost, TW Okell, S Thandeswaran, ...
Proc Intl Soc Mag Reson Med 23, 17, 2015
72015
The system can't perform the operation now. Try again later.
Articles 1–20