Ramon Bragos
Title
Cited by
Cited by
Year
In Vivo and In Situ Ischemic Tissue Characterization Using Electrical Impedance Spectroscopya
O Casas, R Bragos, PJ Riu, J Rosell, M Tresanchez, M Warren, ...
Annals of the New York Academy of Sciences 873 (1), 51-58, 1999
1231999
An analog front-end enables electrical impedance spectroscopy system on-chip for biomedical applications
F Seoane, J Ferreira, JJ Sanchez, R Bragós
Physiological measurement 29 (6), S267, 2008
1212008
Performance of a portable biosensor for the analysis of organophosphorus and carbamate insecticides in water and food
A Hildebrandt, R Bragos, S Lacorte, JL Marty
Sensors and Actuators B: Chemical 133 (1), 195-201, 2008
1122008
A wide-band AC-coupled current source for electrical impedance tomography
R Bragos, J Rosell, P Riu
Physiological measurement 15 (2A), A91, 1994
951994
Transmural versus nontransmural in situ electrical impedance spectrum for healthy, ischemic, and healed myocardium
Y Salazar, R Bragos, O Casas, J Cinca, J Rosell
IEEE Transactions on Biomedical Engineering 51 (8), 1421-1427, 2004
892004
Basics of broadband impedance spectroscopy measurements using periodic excitations
B Sanchez, G Vandersteen, R Bragos, J Schoukens
Measurement Science and Technology 23 (10), 105501, 2012
842012
A new measuring and identification approach for time-varying bioimpedance using multisine electrical impedance spectroscopy
B Sanchez, E Louarroudi, E Jorge, J Cinca, R Bragos, R Pintelon
Physiological measurement 34 (3), 339, 2013
742013
Optimal multisine excitation design for broadband electrical impedance spectroscopy
B Sanchez, G Vandersteen, R Bragos, J Schoukens
Measurement Science and Technology 22 (11), 115601, 2011
722011
On-line monitoring of yeast cell growth by impedance spectroscopy
A Soley, M Lecina, X Gámez, JJ Cairo, P Riu, X Rosell, R Bragos, F Godia
Journal of biotechnology 118 (4), 398-405, 2005
722005
Circuitos y dispositivos electrónicos: Fundamentos de electrónica
LP Viñas, RB Bardia
Edicions UPC, 1999
70*1999
Design and performance of an electrical stimulator for long-term contraction of cultured muscle cells
M Marotta, R Bragós, AM Gómez-Foix
BioTechniques 36 (1), 68-73, 2004
642004
Novel estimation of the electrical bioimpedance using the local polynomial method. Application to in vivo real-time myocardium tissue impedance characterization during the …
B Sanchez, J Schoukens, R Bragos, G Vandersteen
IEEE Transactions on Biomedical Engineering 58 (12), 3376-3385, 2011
602011
Electrical bioimpedance methods
PJ Riu
International Conference on Electrical Bio-Impedance 1998: Barcelona, Spain), 1999
591999
FGF-4 increases in vitro expansion rate of human adult bone marrow-derived mesenchymal stem cells
J Farré, J Farré, S Roura, J Farré, S Roura, C Prat-Vidal, C Soler-Botija, ...
Growth Factors 25 (2), 71-76, 2007
562007
Passive transmission of ischemic ST segment changes in low electrical resistance myocardial infarct scar in the pig
J Cinca, M Warren, A Rodrıéguez-Sinovas, M Tresanchez, A Carreno, ...
Cardiovascular research 40 (1), 103-112, 1998
561998
Development of a Portable Biosensor for Screening Neurotoxic Agents in Water Samples
H Alain, R Jordi, B Ramon, T Marius, L Silvia
Talanta 75 (5), 1208-1213, 0
54*
AD5933-based spectrometer for electrical bioimpedance applications
J Ferreira, F Seoane, A Ansede, R Bragos
Journal of Physics: Conference Series 224 (1), 012011, 2010
512010
A parallel broadband real-time system for electrical impedance tomography
O Casas, J Rosell, R Bragós, A Lozano, PJ Riu
Physiological measurement 17 (4A), A1, 1996
511996
Current source for multifrequency broadband electrical bioimpedance spectroscopy systems. A novel approach
F Seoane, R Bragós, K Lindecrantz
2006 International Conference of the IEEE Engineering in Medicine and …, 2006
482006
Apparatus and procedure for measuring volumes and global and segmental corporal composition in human beings
JR Ferrer, PR Costa, RP Areny, JE Canas, RB Bardia
US Patent 6,151,523, 2000
482000
The system can't perform the operation now. Try again later.
Articles 1–20