Follow
Martin Bues
Martin Bues
Verified email at mayo.edu
Title
Cited by
Cited by
Year
ADVANTAGE OF PROTONS COMPARED TO CONVENTIONAL X-RAY OR IMRT IN THE TREATMENT OF A PEDIATRIC PATIENT WITH MEDULLOBLASTOMA
WH St. Clair, JA Adams, M Bues, JS Loeffler, NJ Tarbell
International Journal of Radiation Oncology* Biology* Physics 58 (3), 727, 2004
4472004
Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas MD Anderson Cancer Center, Proton Therapy Center, Houston
MT Gillin, N Sahoo, M Bues, G Ciangaru, G Sawakuchi, F Poenisch, ...
Medical physics 37 (1), 154-163, 2010
2962010
The MD Anderson proton therapy system
A Smith, M Gillin, M Bues, XR Zhu, K Suzuki, R Mohan, S Woo, A Lee, ...
Medical physics 36 (9Part1), 4068-4083, 2009
2122009
Exploratory study of 4D versus 3D robust optimization in intensity modulated proton therapy for lung cancer
W Liu, SE Schild, JY Chang, Z Liao, YH Chang, Z Wen, J Shen, JB Stoker, ...
International Journal of Radiation Oncology* Biology* Physics 95 (1), 523-533, 2016
1252016
Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning system
XR Zhu, F Poenisch, M Lii, GO Sawakuchi, U Titt, M Bues, X Song, ...
Medical physics 40 (4), 041723, 2013
982013
Impact of respiratory motion on worst-case scenario optimized intensity modulated proton therapy for lung cancers
W Liu, Z Liao, SE Schild, Z Liu, H Li, Y Li, PC Park, X Li, J Stoker, J Shen, ...
Practical radiation oncology 5 (2), e77-e86, 2015
952015
Therapeutic step and shoot proton beam spot-scanning with a multi-leaf collimator: a Monte Carlo study
M Bues, WD Newhauser, U Titt, AR Smith
Radiation protection dosimetry 115 (1-4), 164-169, 2005
852005
Robust intensity‐modulated proton therapy to reduce high linear energy transfer in organs at risk
Y An, J Shan, SH Patel, W Wong, SE Schild, X Ding, M Bues, W Liu
Medical physics 44 (12), 6138-6147, 2017
772017
Robust optimization for intensity modulated proton therapy to redistribute high linear energy transfer from nearby critical organs to tumors in head and neck cancer
C Liu, SH Patel, J Shan, SE Schild, CE Vargas, WW Wong, X Ding, ...
International Journal of Radiation Oncology* Biology* Physics 107 (1), 181-193, 2020
622020
Impact of spot size and spacing on the quality of robustly optimized intensity modulated proton therapy plans for lung cancer
C Liu, SE Schild, JY Chang, Z Liao, S Korte, J Shen, X Ding, Y Hu, Y Kang, ...
International Journal of Radiation Oncology* Biology* Physics 101 (2), 479-489, 2018
612018
Implementation of feedback-guided voluntary breath-hold gating for cone beam CT-based stereotactic body radiotherapy
Y Peng, S Vedam, JY Chang, S Gao, R Sadagopan, M Bues, P Balter
International Journal of Radiation Oncology* Biology* Physics 80 (3), 909-917, 2011
602011
Experimental validation of a Monte Carlo proton therapy nozzle model incorporating magnetically steered protons
SW Peterson, J Polf, M Bues, G Ciangaru, L Archambault, S Beddar, ...
Physics in Medicine & Biology 54 (10), 3217, 2009
562009
Benchmarking analytical calculations of proton doses in heterogeneous matter
G Ciangaru, JC Polf, M Bues, AR Smith
Medical physics 32 (12), 3511-3523, 2005
522005
Dosimetric comparison of distal esophageal carcinoma plans for patients treated with small‐spot intensity‐modulated proton versus volumetric‐modulated arc therapies
C Liu, RS Bhangoo, TT Sio, NY Yu, J Shan, JS Chiang, JX Ding, WG Rule, ...
Journal of applied clinical medical physics 20 (7), 15-27, 2019
512019
Using experimentally determined proton spot scanning timing parameters to accurately model beam delivery time
J Shen, E Tryggestad, JE Younkin, SR Keole, KM Furutani, Y Kang, ...
Medical physics 44 (10), 5081-5088, 2017
482017
Impact of range shifter material on proton pencil beam spot characteristics
J Shen, W Liu, A Anand, JB Stoker, X Ding, M Fatyga, MG Herman, ...
Medical physics 42 (3), 1335-1340, 2015
472015
A critical review of LET-based intensity-modulated proton therapy plan evaluation and optimization for head and neck cancer management
W Deng, Y Yang, C Liu, M Bues, R Mohan, WW Wong, RH Foote, ...
International Journal of Particle Therapy 8 (1), 36-49, 2021
452021
Integrating an open source Monte Carlo code “MCsquare” for clinical use in intensity‐modulated proton therapy
W Deng, JE Younkin, K Souris, S Huang, K Augustine, M Fatyga, X Ding, ...
Medical physics 47 (6), 2558-2574, 2020
452020
Small‐spot intensity‐modulated proton therapy and volumetric‐modulated arc therapies for patients with locally advanced non‐small‐cell lung cancer: a dosimetric comparative study
C Liu, TT Sio, W Deng, J Shan, TB Daniels, WG Rule, PR Lara, SM Korte, ...
Journal of applied clinical medical physics 19 (6), 140-148, 2018
452018
Robust treatment planning with conditional value at risk chance constraints in intensity‐modulated proton therapy
Y An, J Liang, SE Schild, M Bues, W Liu
Medical physics 44 (1), 28-36, 2017
452017
The system can't perform the operation now. Try again later.
Articles 1–20